The most powerful commercial air decontamination technology.

Laboratory proven to destroy airborne viruses and bacteria by up to 99.99999%, the ultimate clean air device for large, open-plan and public spaces of all kinds.

The best air in the business.

Features our most advanced filtration and active decontamination technology, delivering hygienically clean indoor air in businesses, schools, and open-plan spaces up to 280m.

Destroys airborne viruses and bacteria by up to 99.99999%

This unit uses advanced, multi-stage purification and active decontamination for cutting-edge clean air performance, and features a unique airflow and air delivery system for real-time protection.

INTAKE

Continuously draws contaminated air away from the breathing zone in a room by creating a downward airflow, pulling exhaled air away from occupants.

FILTRATION

Multi-stage filtration features a pre-filter, granular activated carbon, and dual H14 HEPA filters to remove coarse, fine, and ultrafine particulates and VOCs.

DECONTAMINATION

Our patented UV-C Reactor Chamber uses a powerful, safe photochemical process that actively deactivates airborne viruses and bacteria for real-time indoor air hygiene.

AIR DELIVERY

Returns air directly to the breathing zone at head height, providing a constant flow of clean air without the delay required for an entire room’s air to be exchanged.

Targeted air delivery at head height.

Designed to provide clean air to people, not just to the room. The tower form factor means direct access to clean, fresh air for guests, staff, and visitors even in crowded or busy environments.

Safety Certified.

Ozone free. No UV leakage. This unit has achieved the highest levels of regulatory and compliance certification and adheres to rigorous global electrical, emissions and safety standards.

Built tough for busy public spaces.

A powder-coated steel chassis and robust build quality make this unit a reliable feature of any high-traffic, public or busy retail or commercial space.

i One air change per hour based on 2.4m (7.8ft) ceiling height.
ii Sound pressure level calculated from sound power level as tested against ISO 3744.
iii The built-in VOC sensor calibrates each time the device powers on.
iv Measured at highest fan speed.
v Dependent on operating environment.

1 As tested against Staphylococcus Epidermidis (7.9-log reduction), MS2 bacteriophage (6.59-log reduction) after 90 min; Pantoea Agglomerans (5.73-log reduction) after 60 min; and Phi X 174 bacteriophage (5.96-log reduction) after 45 min. Tests performed by ARE Labs in the United States on the highest fan speed in a 16m3 chamber. Air purifiers are intended for use as part of an overall air quality plan and are not intended to treat, cure, or prevent any disease.
2 Tests performed by ARE Labs in the United States on the highest fan speed in a 16m3 chamber.
3 Ozone: The VK Pro emits less than 0.005 ppm of ozone, over a 24-hour period, which falls below the acceptable zero-ozone emission limit required by leading authorities on consumer safety standards in North America. UV: With filters removed, total irradiance measured at 0cm from all device outlets is less than 1 mW/m2